Medical Trolley Transport ICU Anesthesia Machine
Description:
Patient Centered Ventilation: Precision in an anesthesia ventilator, from conventional ventilation to advanced modes and adapt to wide range patient.
Safety design: Vaporizer with temperature, pressure, flow compensation and self-lock function. Real time pressure-time, flow-time loop oscillogram and high precision ETC02, 02 concentration detection function included.
Alarm: 13 alarms to make sure the safety. Three level alarm system, visual and sound alarm information
Built-in battery ensure 2-3 hours using when power failure
Visible sell-checking system: Make sure the safety of all parts.
Before setting parameters, choose freely type of patients: adult, children and neonatal. Also preset the age of patient.
Separate design of electric circuit and gas circuit ensure long using life.
Language: 8 languages for exchange including Chinese, English, Spanish, French, Russian, Turkish, German, Portuguese.
Specification:
Anesthesia Machine Detailed Description:
6 auxiliary plugs
Plugs of monitors can be inserted.
VGA RS232 USB connector and ETCO2
Connect with hospital's system and cutput patient information.
End-tidal carbon dioxide concentration monitoring, real-time understanding of the stale of the patient.
AGSS (optional part)
To enhance the safety of the environment in which members of staff in close proximity with waste anesthetic gases and vapors (agents)work.
Other optional parts
Anesthetic gas monitor, Vial signs monitor: Real-time monitoring of anesthetic gas and patient's
physiological condition.
Ventilator parameter range:
Tidal volume(Vt): 0. 10ml~1500ml
Frequence (Freq): 4/min~100/min
I:E: 4:1~1:10
Rapid oxygen supply: 25 L/min- 75 L/min
Pressure trigger: -1 cmH2O~ -20 cmH2O
Flow rigger: 0.3L/min, 1 L/min - 15 L/min
Pressure support: 3 cmH2O~50 cmH2O
Pressure limit: 10 cmH2O - 100 cmH2O
Inspiration apnea: OFF, 5%-60 %
Inspiration time: 0.2s-5s
Trigger: 5 %-95 %
SIMV frequency: 4 /min~ 60 /min
Rise time: 0s~2s.
Alarm and protection:
VT upper limit: 5mL - 2000mL
VT lower limit: 0mL-1995mL
MV upper limit: 0.1 L/min - 100 L/min
MY lower limit: 0.0 L/min - 99.9 L/min
Respiration frequency upper limit: 2 /min- 100 /min
Respiration frequency lower limit: 0/min - 98 /min
FIO2 upper limit: 20 %- 100%
FIO2 lower limit: 18 %-98 %
Airway pressure upper limit: 2 cmH2O - 100 cmH2O
Airway pressure lower limit: 0 cmH2O - 98 cmH20
Apnea: 20s-40s
Oxygen concentration never lower than 25% when N2O start
Anesthesia Machine Real Scene Shoots:
Description:
Patient Centered Ventilation: Precision in an anesthesia ventilator, from conventional ventilation to advanced modes and adapt to wide range patient.
Safety design: Vaporizer with temperature, pressure, flow compensation and self-lock function. Real time pressure-time, flow-time loop oscillogram and high precision ETC02, 02 concentration detection function included.
Alarm: 13 alarms to make sure the safety. Three level alarm system, visual and sound alarm information
Built-in battery ensure 2-3 hours using when power failure
Visible sell-checking system: Make sure the safety of all parts.
Before setting parameters, choose freely type of patients: adult, children and neonatal. Also preset the age of patient.
Separate design of electric circuit and gas circuit ensure long using life.
Language: 8 languages for exchange including Chinese, English, Spanish, French, Russian, Turkish, German, Portuguese.
Specification:
Product name | Medical Trolley Transport ICU Anesthesia Machine |
Ventilation mode | P-CMV, V-CMV, P-SIMV, V-SIMV, PSV, PRVC, SIGH, MANUAL |
Ventilator parameter range | Tidal volume(Vt): 0. 10ml~1500ml Frequence (Freq): 4/min~100/min I:E: 4:1~1:10 Rapid oxygen supply: 25 L/min- 75 L/min Pressure trigger: -1 cmH2O~ -20 cmH2O Flow rigger: 0.3L/min, 1 L/min - 15 L/min Pressure support: 3 cmH2O~50 cmH2O Pressure limit: 10 cmH2O - 100 cmH2O Inspiration apnea: OFF, 5%-60 % Inspiration time: 0.2s-5s Trigger: 5 %-95 % SIMV frequency: 4 /min~ 60 /min Rise time: 0s~2s . |
Monitoring parameter | Frequence (Freq): 0/min~100/min Tidal volume(Vt): 0mL~2500mL Minute volume: 0L/min~99.9L/min Oxygen concentration: 15%~100% Airway pressure: -20 cmH2O- 100 cmH2O Inspiration platform pressure: 0 cmH2O~100 cmH2O PEEP: 0 cmH2O~70 cmH2O I:E: 4:1 ~1:10 |
Oscillogram | P-T (pressure - time) F-T (flow- time) V-T (volume - time ) ETC02-T (ETC02 - time) P-V loop(pressure-volume loop) F-V loop(flow-volume loop)F-P loop(flow-pressure loop) |
Alarm and protection | VT upper limit: 5mL - 2000mL VT lower limit: 0mL-1995mL MV upper limit: 0.1 L/min - 100 L/min MY lower limit: 0.0 L/min - 99.9 L/min Respiration frequency upper limit: 2 /min- 100 /min Respiration frequency lower limit: 0/min - 98 /min FIO2 upper limit: 20 %- 100% FIO2 lower limit: 18 %-98 % Airway pressure upper limit: 2cmH2O - 100 cmH2O Airway pressure lower limit: 0cmH2O - 98 cmH20 Apnea: 20s-40s Oxygen concentration never lower than 25% when N2O start |
Testing | Automatic leakage compensation testing Patient circuit leakage compensation and automatic compliance compensation Patient monitor and AG monitor can be equipped Manual ventilation, mechanical ventilation and standby Oscillogram: P-T, F-T, V-T, Lung function loop, ETCO2 Self-testing visible Alarm visible ACGO function |
Packing size | Wooden case packing size: L870*1000*1600mm G.W: 240KG N.W.: 165KG CBM: 1.392m² |
Anesthesia Machine Detailed Description:
6 auxiliary plugs
Plugs of monitors can be inserted.
VGA RS232 USB connector and ETCO2
Connect with hospital's system and cutput patient information.
End-tidal carbon dioxide concentration monitoring, real-time understanding of the stale of the patient.
AGSS (optional part)
To enhance the safety of the environment in which members of staff in close proximity with waste anesthetic gases and vapors (agents)work.
Other optional parts
Anesthetic gas monitor, Vial signs monitor: Real-time monitoring of anesthetic gas and patient's
physiological condition.
Ventilator parameter range:
Tidal volume(Vt): 0. 10ml~1500ml
Frequence (Freq): 4/min~100/min
I:E: 4:1~1:10
Rapid oxygen supply: 25 L/min- 75 L/min
Pressure trigger: -1 cmH2O~ -20 cmH2O
Flow rigger: 0.3L/min, 1 L/min - 15 L/min
Pressure support: 3 cmH2O~50 cmH2O
Pressure limit: 10 cmH2O - 100 cmH2O
Inspiration apnea: OFF, 5%-60 %
Inspiration time: 0.2s-5s
Trigger: 5 %-95 %
SIMV frequency: 4 /min~ 60 /min
Rise time: 0s~2s.
Alarm and protection:
VT upper limit: 5mL - 2000mL
VT lower limit: 0mL-1995mL
MV upper limit: 0.1 L/min - 100 L/min
MY lower limit: 0.0 L/min - 99.9 L/min
Respiration frequency upper limit: 2 /min- 100 /min
Respiration frequency lower limit: 0/min - 98 /min
FIO2 upper limit: 20 %- 100%
FIO2 lower limit: 18 %-98 %
Airway pressure upper limit: 2 cmH2O - 100 cmH2O
Airway pressure lower limit: 0 cmH2O - 98 cmH20
Apnea: 20s-40s
Oxygen concentration never lower than 25% when N2O start