Medical Equipment 15" High Definition LCD Display Black and White Cart Ultrasound Scanner

1Monitor15 inch LCD screen2Resolution1024*768 pixels3Scanning methodconvex/linear/micro-convex4Probe ports3 active5Integrated probe holder66LanguageChinese/English7Display modeB, B+B, 4B, B+M, MTissue Harmonic Imaging(THI)8FocusElectronic focus, position adjustable9Body mark40 kinds10Probe frequency2.5-8.5MHz multi-frequenc

Featured Products

1Monitor15 inch LCD screen
2Resolution1024*768 pixels
3Scanning methodconvex/linear/micro-convex
4Probe ports3 active
5Integrated probe holder6
6LanguageChinese/English
7Display modeB, B+B, 4B, B+M, M
Tissue Harmonic Imaging(THI)
8FocusElectronic focus, position adjustable
9Body mark40 kinds
10Probe frequency2.5-8.5MHz multi-frequency, 4 selectable frequency for each probe, can be customized
11Image modeup/down, left/right
12Clinical applicationsAbdominal; OB/GYN; Urology; Cardiac; Breast; Small Parts, Thyroid; etc
13Measurement packageGeneral:
Distance, perimeter/area (by FREEHAND or ELLIPSE), volume
OB&GYN:
With two kinds of obstetric table for options: Tokyo and HADLOCK
BPD-FW, FL, AC, HC, CRL, AD, GS, LMP, EDD, AFI
Cardiac:
LV (VF): left ventricular
RHWD --- Diastolic right wall thickness (mm)
RHWS --- Systolic right wall thickness (mm)
RVD --- Diastolic right ventricular diameter (mm)
RVS --- Systolic right ventricular diameter (mm)
LVDD --- Diastolic left ventricular diameter (mm)
LVDS --- Systolic left ventricular diameter (mm)
PLVWD --- Diastolic left ventricular posterior wall thickness (mm)
PLVWS --- Systolic left ventricular posterior wall thickness (mm)
IVSD --- Diastolic interventricular septum thickness (mm)
IVSS --- Systolic ventricular septal thickness (mm)
LVEDV --- Diastolic left ventricular flow (ml)
LVESV --- Left ventricular flow at the end of systole (ml)
SF --- Systolic fraction (%)
EF --- Ejection fraction (%)
SV --- Stroke volume (ml)
CO --- ECG output (ml)
AV: Aortic Valve
AO --- End diastolic aortic root diameter (mm)
LA --- Left atrial diameter at the end of systole (mm)
AVO --- Aortic anterior leaflet and posterior leaflet distance (mm)
LAR --- Left atrium/aorta ratio
LVET --- Left ventricular ejection time (seconds)
MV: Mitral Valve
DE<EX> --- Distance from point D to point E on the Y axis (mm)
EF<EX> --- Distance from point E to point F on the Y axis (mm)
DE<TM> --- DE time (seconds)
EF<TM> --- EF time (seconds)
DE<SL> --- Slope = (point E on the Y-axis - point D on the Y-axis) / (point F on the X-axis - point D on the X-axis) (mm/sec)
EF<SL> --- Slope = (point E on the Y-axis - point F on the Y-axis) / (point F on the X-axis - point E on the X-axis) (mm/sec)
PV: Pulmonary Valve
A<DEP> ---Depth:
The F to A distance is the distance from the beginning of the atrial systole to the maximum downward position of the pulmonary valve. The distance from F to A in the Y-axis indicates the maximum range of motion of the atrial systolic pulmonary valve.
A<DEP>depth=AY-FY (mm)
AY is the point A on the Y axis, and FY is the point F on the Y axis.
EF<SL> --- Slope:
When the initial blood flows out of the atria, E1 is the starting point of the ventricular diastolic phase, and F
is the starting point of the atrial systolic inflow.
EF<SL>slope=(FY-E1Y)/(FX-E1X)(mm/s)
FY is the F point on the Y axis, E1Y is the E1 point on the Y axis, FX is the F point on the X axis, and E1X
is the E1 point on the X axis.
BC<DS> --- diameter:
BC is the ventricular systolic pulmonary valve opening, and the upper part of the Y-axis is the leaflet moving distance when the pulmonary valve is opened to the maximum.
BC<DS>diameter=CY-BY(mm)
CY is the C point on the Y axis, and BY is the B point on the Y axis.
BC<SL> --- Slope:
BC<SL>slope = (CY-BY) / (CX-BX) (mm/s)
CY is the C point on the Y axis, BY is the B point on the Y axis, CX is the C point on the X axis, and BX is the B point on the X axis.
RVET --- Right ventricular ejection time:
Right ventricular ejection time is the time from point B to point E2 when the pulmonary valve is open.
RVET=E2X-BX (seconds)
E2X is the E2 point on the X axis, and BX is the B point on the X axis
TV: Tricuspid Valve
DE<EX> --- D point on the Y axis (the right ventricle before the tricuspid opening) to the point E (the tricuspid opening to the maximum) distance (mm)
EF<EX> --- Distance from point E to point F on the Y axis (mm)
DE<TM> --- DE time (seconds)
EF<TM> --- EF time (seconds)
DE<SL> --- Slope = (point E on the Y-axis - point D on the Y-axis) / (point F on the X-axis - point D on the X-axis) (mm/sec)
EF<SL> --- Slope = (point E on the Y-axis - point F on the Y-axis) / (point F on the X-axis - point E on the X-axis) (mm/sec)
HR: Heart Rate
TM --- Time (seconds)
HR --- Heart rate (times / minute)
14Report formatAB/GYN, Cardiac, OB, Urology
15NoteName, PID, Age, Gender, Notes, Time, Hospital, Doctor, Obstetrics table, Language, Histogram
16Cine loop655 frames, can be customized to 1200 frames
17Storage64 images as standard, with external USB for data storage and transfer
18Gravel positioningAs standard
19Dynamic range64-192dB
20TGC8 segment
21Pre-processVariable aperture, dynamic apodization, dynamic digital filtering, etc.
22Post processFrame correlation, dot line correlation, 7 pseudo color processing, etc.
23Blind zone≤4
24Max scanning depth250mm
25Geometric accuracylateral ≤ 5%, longitudinal ≤ 5%
26Resolutionlateral ≤ 2mm, axial ≤ 1mm
27InterfaceSVGA output, Video, USB
28Magnification30 display modes
29Gain control0~100
30Power supply100-240V, 50/60Hz
 
1Machine AppearanceSize: 740x520x1210mm (L*W*H)
NW: 26.6kg, GW of Package: 38.5kg
Packing size:81*61*96cm (L*W*H)
2StandardMain unit with integrated trolley *1
15 inch LCD monitor *1
Earth Wire *1
Adapter *1
Trestle *1
Fuses *8
Convex probe *1
User manual (in English) *1
3OptionsProbes:
Linear probe
Trans-vaginal probe
Trans-rectal probe
Micro-convex probe
Thermal printer: SONY UP-X898MD, MITSUBISHI P93W-Z
Thermal paper
Biopsy attachment: for convex, linear, trans-vaginal and rectal probes
4CertificateFree Sale Certificate
CE (issued by TUV)
ISO13485 (issued by TUV)
5WarrantyTwo-year free warranty for machine and probes, lifetime maintenance

FAQ


Q: Do you accept OEM or ODM orders?
A: OEM and ODM .Please contact us for our OEM and ODM cases for your kindly information.

Q: What are your payment terms?
A: T/T and L/C 


Q: What is your QA/QC policy?
A: We have complete QA/QC regulations and strictly obey the regulations during the all production procedures. 