Medical Anesthesia Equipment Cart (THR-MJ-8600A)

THR-MJ-8600A Medical Anesthesia MachineWith two VP300 VaporizersCE High Quality! !Features:1) PCV and SIMV+PS modes ensure flexibility in ventilation, machine doable for both pediatric and adult operation2) Optional functions monitoring O2, CO2, and anesthetic gas3) Flowmeter provides minimum 25% concentration of oxygen in O2 /N

Featured Products

Medical Anesthesia Equipment Trolley (THR-MJ-8600A)
THR-MJ-8600A Medical Anesthesia Machine
With two VP300 Vaporizers
CE High Quality! !

Features:
1) PCV and SIMV+PS modes ensure flexibility in ventilation, machine doable for both pediatric and adult operation
2) Optional functions monitoring O2, CO2, and anesthetic gas
3) Flowmeter provides minimum 25% concentration of oxygen in O2 /N2O mixtur
4) Absorb system sterilized with high temperature and high pressure
5) Enhances usability with auxiliary oxygen, suction, auxiliary power source, monitor arm, infusion pump etc.

Vaporizer VP300
· Support two vaporizers
· Agent: Halothane, Enflurane, Isoflurane, Sevflurane.
· Installation Mode: Selectatec with interlock
· Filling Type: Pour Fill, Key Fill, Quik-Fil
 Dimensions(W×H×D): 712mm ×1400mm ×780mm
 Weight: 115kg (including trolley base and 2 vaporizers, without cylinder)
 Operation Temperature: +10~+40°C
 Operation Humidity:  ≤80% (noncondensing)
 Storage Temperature: -20~+55°C
 Storage Humidity:  ≤93%(noncondensing)
 Mains: 100-240V AC, 50-60Hz
 Battery:  24V 5Ah, minimum 120 min
 Gas Supply : Air,O2,N2O; 280kPa - 600kPa
 Flowmeters:  O2 Range: 0-1L/min; 1-10L/min
N2O Range: 0-1L/min; 1-10L/min
Air Range: 0-1L/min; 1-10L/min
Auxiliary O2 Range: 0 -15 L/min
 Gas System: Flowmeter backlight
Low O2 signal
N2O-cut-off system
O2 flush: 25-75L/min
 Operational Modes: Closed, Semi-closed, Semi-open
 Carbon Dioxide Absorbent Canister: 2 Loose fill(3L) or 2 prepacks
 APL Range: Spontaneous breathing (SP) -70 cmH2O
 Material:  Autoclavable (except flow sensors, O2 fell cell and mechanical pressure meter)
  
 Driven Modes: Pneumatically driven and electronically control
 Patient Types: Adult & children
 Ventilation Modes: IPPV, PCV, SIMV, PS, and Manual
 Setting Modes: Touch key & navigator wheel knob
 Tidal Volume:  20-1500ml
 Ventilation Frequency: 4-100bmp
 I:E Ratio:  4:1-1:8
 Pressure (inspired) Range: 5-70cmH2O
 Pressure (support) Range: 3- 50cmH2O
 Ppeep:  off,3-30 cmH2O
 Tslope: 0-2s
 Inspiratory Plateau: off, 5%-60%Ti,
 Trigger Sensitivity: 1-15L/min
 peak gas flow75L/min
 Compensation Compliance compensation, fresh gas compensation
  Ventilator Monitoring 
 Display: 10.4"TFT color screen
 Pressure: Paw, Peak, Pplat, Pmean, PEEP
 Volumes:  MV, Vt
 Gas: O2 Concentration, CO2 Concentration, Anesthesia Agent Concentration
 Graph Display: P-T, F-T&P-V,F-V loops(can be saved), Wave of CO2
 Alarm
 Pressure: Paw high/low limit
 Volumes:  MV high/low limit,
 Gas:  FiO2 high/low limit
 Power failure 
 Apnea Alarm:  60 seconds
 Alarm Silence: 110 seconds

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours